Rolling bush system

Standard: 7231

Rolling bush system for system guide pillars for minimal wear and precise closing of the tool halves without offset

Advantages

    Combined guiding and centering

    • Highest system precision thanks to backlash-free preloaded profile rollers. Five to twelve times longer service life than conventional sliding guides
    • Space saving enables higher production with the same tool size
    • Easiest handling: low maintenance, durable and no pairing required despite roller guide
    • Displaceable retaining ring (standard 8005) enables use across several plate thicknesses
    • Can be combined with all guide pillars from the Agathon product range
Guiding and centering
Konzepte im Vergleich

Konzepte im Vergleich

Guiding and centering concept

    Conventional approach

    • Combination of two different systems in the mold
    • The guide pillars only take over the coarse alignment of the mold during most of the closing movement 
    • Only on the last millimeters of the closing stroke do the flat centering devices take over the fine alignment
    • This can be a problem with long, or sensitive mold areas
    • The flat guides are subject to relatively high wear


    The Agathon concept


    • The Agathon Guiding System Plus takes over all guiding and centering tasks with just one assembly over almost the entire clamping stroke
    • Smooth and highly precise guidance thanks to preloaded profile roller cage
    • No jerky sliding during mould movements
    • Easy handling: Low maintenance, durable, no pairing required despite roller guide 
    • Nearly wear-free

Cost benefits
Konzepte im Vergleich

Konzepte im Vergleich

Advantages of the Agathon concept

    Previous approach 
    • Four main guides and four flat centering devices are required
    • The production of the pockets for flat centering devices is complex, time-consuming and imprecise
    • Two systems in the tool require valuable space
    • Precision depends on manufacturing tolerances and wear condition of the guiding and centering elements
    • High lubricant and maintenance requirements
    • Dirt ingress due to abrasion and particle formation

    The Agathon concept
    • Pocket production for flat centering is no longer necessary, which saves time and costs
    • Enlarging the working area by up to approx. 30% for additional cavities, slides or tempering
    • Thanks to backlash-free preloaded guides with profile rollers, precision remains at the highest level over the entire service life
    • Low lubricant and maintenance requirements increase the productivity of the system, reduce maintenance costs and protect the environment

Product features

Key features and highlights

    Retaining ring (standard 8005) enables adaptation to different plate thicknesses:
    • The roller bushing can be adapted to different plate thicknesses by positioning the retaining ring accordingly
    • The ring, which can be reordered as a spare part, can be used with roller bushing system 7231 and system guide pillar 6701
    • Safe fixing thanks to heat-resistant O-ring (up to 200 °C) 


    Long centering travel:
    • Tool is already centered when the preload is reached
    • Abrasion on spotting surfaces and plunging cores is prevented
    • Tool service life is significantly increased

    Optimized for high-end applications:
    • Minimum quantity lubrication is sufficient
    • Rolling bush with brass profile roller cage allows cleaning in an ultrasonic bath and temperatures up to 170 °C
    • Optimal for clean room, high-precision, micro-injection molding and high-temperature applications
    • Significantly higher travel speeds and therefore higher production output possible

Advantages of the Agathon Guiding System Plus
Flexibility - One for all

Flexibility - One for all

Advantages at a glance

    Flexibility thanks to adaptability to different plate thicknesses using retaining rings:
    • Thanks to this concept, only one size is required in stock. The guide can continue to be used if the tool and plate thicknesses change
    • Compatibility: retrofitting to tools is possible without reworking plates
    • No pairing required: Any bushing of the appropriate diameter of standard 7231 can be combined with any system guide pillar of standard 6701 of the appropriate diameter from the Agathon product range. Attention: Do not exceed length l2max
    • Spare parts available from stock

    Better utilization of the clamping surface:
    • The division of tasks between main guide and end centering is eliminated
    • Simplification of the tools: Fewer components and less space required on the clamping surface, significantly lower manufacturing and assembly costs
    • Thus more cavities and higher productivity on the same clamping surface
    • Existing flat centering devices can be removed when retrofitting the Agathon Guiding System Plus

    More service life and precision:
    • Backlash-free preloaded guide with profile roller cage ensures maximum precision and part quality over the entire service life of the tool
    • The service life is 5-12 times longer compared to conventional systems
    • High process reliability avoids rejects and production stops
    • Lower maintenance requirements and higher productivity

Scope of delivery: incl. 1 ring clamp standard 8005 in the respective diameter.
Material of bush and rollers: 100Cr6 (1.3505), hardened 62-64 HRC
Material of cage: brass CuZn39Pb3 (2.0401)
Temperature resistance: up to approx. 170°C

Scope of delivery: incl. 1 ring clamp standard 8005 in the respective diameter. Material of bush and rollers: 100Cr6 (1.3505), hardened 62-64 HRC Material of cage: brass CuZn39Pb3 (2.0401) Temperature resistance: up to approx. 170°C

Technical data

d1  =
Corresponding pillar diameter
d3  =
Outer diameter of the guide bush
d8  =
Outer diameter of the retaining ring (flexible collar)
 =
Entry into the preload (l2max - l5max)
l1  =
Overall length of the guide bush
l2 min  =
Recommended min. immersion depth using shortest 6701 pillar with thickest bracing plate l6
l2 max  =
Maximum immersion depth when using longer pillars
l3  =
Mounting positions of the retaining ring (flexible collar)
l5 max  =
Maximum possible centering path when using longer pillars
l6 (mm)  =
Lift-off plate (see standard 6701)
l8  =
Width of the retaining ring (flexible collar)
f max  =
Maximum centering offset at the start of centering
Entrance C  =
Basic dynamic load rating in [N] - Initial load capacity
Closed C0 (l2max)  =
static load rating in N at l2max, tool closed
Closed C0 maxP  =
static load rating in N at l2min (using thickest recommended wiper plate l6)
Dimensional drawing Installation tolerances

Dimensional drawing Installation tolerances

Accuracy requirements

    Installation tolerances:

    • The pillar and bushing are installed in bores with tolerance H5
    • Alternatively, if less accuracy is required, the tolerance H6 can be used
    • Pay attention to the installation direction (FRONT)


    Rectangularity:

    • If the largest hole spacing of the main pillar is less than 250 mm, the perpendicularity of the locating hole to the parting line should be <0.005 mm per 100 mm length of the guide pillars.
    • If the largest hole spacing of the main pillar is greater than 250 mm the perpendicularity of the mounting hole to the parting plane should be <0.010 mm per 100 mm length of the guide pillars.


    Position tolerances:

    • If the largest hole spacing of the main pillar is less than 250 mm the positional accuracy should be <0.01mm (i.e. ±0.005 mm)
    • If the largest hole spacing of the main pillar is greater than 250 mm the positioning accuracy should be <0.02mm (i.e. ±0.01 mm)
    • Recommendation for best performance: pre-drilled plates with sanding allowance to the desired tolerance or have plates produced with the recommended tolerance


    * = Depending on the required accuracy, the following plates can be be cut to size for easier assembly

Image installation and removal

Image installation and removal

Assembly, disassembly and maintenance of the Guiding System Plus

    Assembly:
    • Clean and remove corrosion protection before assembly, then lubricate 
    • Position the retaining ring correctly, insert the O-ring
    • Tap into the fit with light blows, use a rubber mallet or spacer
    • Do not tap the retaining ring or ring clamp

    Dismantling:
    • Use a rubber mallet or spacer
    • Do not tap the retaining ring, ring clamp or cage
    • Do not pull on the ring clamp

    Maintenance:
    • Regularly rotate the bushing and pillar by 60°
    • First remove the old grease completely, then apply new grease
    • Minimum quantity lubrication is sufficient
    • When replacing the O-ring, observe temperature resistance (FKM)

Führung einer Abstreifplatte

Führung einer Abstreifplatte

Guidance of a wiper plate on the column

Guidance of a wiper plate on the column


Guidance of ejector plates (short stroke)

Guidance of ejector plates (short stroke)

Main guide in the stack mold

Main guide in the stack mold

Main guide for turning tools

Main guide for turning tools

Centering for handling

Centering for handling

More Information
Application type 1 Center, Lead

Available Dimensions

Grouped product items
Item number: 7231.015.085.080 Availability d1 (mm) 15 d3 (mm) 30 d8 (mm) 35 l1 (mm) 85 l2 min (mm) 48 l2 max (mm) 80 l5 max (mm) 62 l8 (mm) 6 Entrance C 1850 Closed C0 (l2max) 5600 Closed C0 maxP 4500 f max (mm) 0.2
Item number: 7231.025.095.086 Availability d1 (mm) 25 d3 (mm) 42 d8 (mm) 47 l1 (mm) 95 l2 min (mm) 53 l2 max (mm) 86 l5 max (mm) 67 l8 (mm) 6 Entrance C 2400 Closed C0 (l2max) 8700 Closed C0 maxP 5800 f max (mm) 0.2
Item number: 7231.032.108.100 Availability d1 (mm) 32 d3 (mm) 54 d8 (mm) 59 l1 (mm) 108 l2 min (mm) 68 l2 max (mm) 100 l5 max (mm) 78 l8 (mm) 10 Entrance C 3650 Closed C0 (l2max) 13200 Closed C0 maxP 11000 f max (mm) 0.2
Item number: 7231.040.128.122 Availability d1 (mm) 40 d3 (mm) 66 d8 (mm) 71 l1 (mm) 128 l2 min (mm) 69 l2 max (mm) 122 l5 max (mm) 100 l8 (mm) 10 Entrance C 4950 Closed C0 (l2max) 21000 Closed C0 maxP 15000 f max (mm) 0.2
Item number Availability d1 (mm) d3 (mm) d8 (mm) l1 (mm) l2 min (mm) l2 max (mm) l5 max (mm) l8 (mm) Entrance C Closed C0 (l2max) Closed C0 maxP f max (mm)
Log in and create a reqeust

If your desired dimensions are not available in this list, select the most suitable one and note your specifications in the inquiry.